ModelVermogenAfmetingen (BxHxD)
Continuity 10001000 VA / 800 W440 x 88 x 405 mm
Continuity 20002000 VA / 1600 W440 x 88 x 650 mm
Continuity 30003000 VA / 2400 W440 x 88 x 650 mm
Continuity 60006000 VA / 5400 W440 x 88 x 680 mm
Continuity 1000010000 VA / 9000 W440 x 132 x 680 mm
Models Alpha Continuity 1000 Alpha Continuity 2000 Alpha Continuity 3000
Input
Voltage Window 60~144Vac for 120V system
Frequency 50/60+/-5% (Auto Sensing)
Phase/Wire Single, Line, + Neutral + Ground
Power Factor >0.99 (Full Load)
Output
Voltage 100/110/115/120/127Vac
Voltage Regulation <±0.1% until low battery warning
Capacity 1000VA/800W 2000VA/1600W 3000/2400W
Power Factor 0.8* Lagging
Wave Form Sine Wave, THD<3% (no load to full load)
Frequency Stability ±0.1% unless synchronized to line
Frequency Regulation 3Hz or 1Hz (Setting by software)
Transfer Time 0 m sec
Crest Factor 3:1
Efficiency (AC to AC) >85% >88%
Autonomy (Built-in Battery) 7.9 mins 6.5 mins
DC Start Yes
Battery
Type Sealed Lead Acid Maintenance Free
Capacity 7Ah 9Ah
Quantity 3 6
Voltage 36Vdc 72Vdc
Recharge Time 3 hours to 90%
Built-in Charger
(max. Charging Current)
1.8A 2.1A 2.7A
Models Continuity 1000 Continuity 2000 Continuity 3000
Display
LED Normal, Battery, Bypass, Programmable Outlet 1, Programmable Outlet 2, Self-Test, Battery Weak & Bad, Site Wiring Fault , Fault, Overload, and Load/Battery Level conditions.
Key On button / Off button (Test / Alarm silence button)
Self-Diagnostics Upon Power On and Software Control
Communication Slots Relay contact board or SNMP card
Protection
Overload AC Mode & Backup Mode (delay before switching to bypass) <105% continuously.
>106%~120% for 30 seconds transfer to bypass
>121%~150% for 10 seconds transfer to bypass
>150% immediately transfer to bypass
Buzzer continuously alarms
Bypass Mode <105% continuously.
>106%~120% for 250 seconds shut down
>121%~130% for 125 seconds shut down
>131%~135% for 50 seconds shut down
>136%~145% for 20 seconds shut down
>146%~148% for 5 seconds shut down
>149%~157% for 2 seconds shut down
>158%~176% for 1 seconds shut down
>177%~187% for 0.32 seconds shut down
>188% for 0.16 seconds shut down
Buzzer continuously alarms
Short Circuit Hold Whole System
Overheat AC Mode: Switch to Bypass; Backup Mode: UPS shuts down immediately
Battery Low Alarm and Switch Off
EPO UPS shuts down immediately
Battery Advanced Battery Discharge Management (ABDM)
Noise Suppression 115V System 400 Joules
230V System 300 Joules
Alarms
Audible and Visual Line Failure, Battery Low, Overload, System Fault Conditions
Computer Interface
Interface Type Standard RS232 and USB Interfaces
Communication Slots Relay Contact board or SNMP card
Mechanical
Models Continuity 1000 Continuity 2000 Continuity 3000
Dimensions mm 440W x 88H x 405D 440W x 88H x 650D
inch 17.3W x 3.5H x 16D 17.3W x 3.5H x 25.6D
Outlets 120Vac 6xNEMA 5-15R 2×5-15R + 2 x 5-20R 4×5-15R + 1xL5-30R
Outlets 230Vac 6 x IEC320-C13 4 x IEC320-C13
1 x IEC320-C19
Net Weight 15.1kg (33.3lbs) 27.9kg (61.5lbs) 29.7kg (65.4lbs)
Environmental
Operating Temperature 0-40°C (32-104°F)
Altitude 0~2000m/6600ft up to 40°C (104°F), 3000m/9900ft up to 35°C (95°F)
Humidity 90% RH Maximum, Non-Condensing
Noise <50dB (at 1 meter/3.3ft)
Agency Compliance
Quality Assurance ISO9001 Certified Company
Safety Standard EN62040-3 complied
Performance EN62040-3 complied
EMC Standard EN62040-2, EN61000-3-2, EN61000-3-3, FCC Class A
Marks CE, UL, cUL, FCC
Battery Pack
Model Continuity 1000 Continuity 2000 Continuity 3000
Battery Type 7Ah 9Ah
Maximum Quantity 12pcs
Output Voltage 36Vdc 72Vdc
Weight Without Batteries 8kg (17.7lbs)
Weight With Batteries 38kg (83.7lbs)
Dimensions mm 88H x 440W x 650D
inch 3.5H x 17.3W x 25.6D
Models Alpha Continuity 6K Alpha Continuity 10K
Input
Voltage Window 160~280Vac
Frequency 45-65Hz
Phase/Wire Single, Line + Ground
Power Factor Up to 0.99 at 100% Linear Load
Current THD (100% linear load) <7%
Output
Voltage Window 200/208/220/240Vac Selectable (208/120Vac optional)
Voltage Adjustment Nominal +1%, +2%, +3%, -1%, -2% or -3%
Voltage Regulation ±1% ±2%
Capacity 6000VA/5400W 10000VA/9000W
Rated Power Factor 0.9 Lagging 0.9 Lagging
Wave Form Sine Wave, THD<3% (no load to full load)
Frequency Stability ±0.2% (Free Running)
Frequency Regulation ±1Hz; ±3Hz
Transfer Time 0ms
Crest Factor 3:1
Efficiency (AC to AC, Normal) Up to 90%
Efficiency (AC to AC, ECO) Up to 95%
Autonomy 7.1 mins 4.8 mins
DC Start Yes
Battery
Type Sealed Lead Acid Maintenance Free
Capacity 12V/7Ah 12V/9Ah
Quantity 20pcs
Voltage 240Vdc
Recharge Time 4 hours to 90% 5 hours to 90%
Display
Status On LED + LCD Line Mode, Backup Mode, ECO Mode, Bypass Supply, Battery Low, Battery Bad/Disconnect, Overload, Transferring with interruption & UPS Fault.
Readings on LCD Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature
Self-Diagnostics Upon Power-on, Front Panel Setting & Software Control, 24-hour routine checking
Alarms
Audible and Visual Line Failure, Battery Low, Transfer to Bypass, System Fault Conditions
Protection
Overload
(w/simulated thermal tripping I-T Curve)
Inverter Supply:
105%~150% for 160 seconds ~ 2 cycles before switching bypass.
Bypass Supply:
105%~200% for 500 seconds ~8 cycles before stopping supply load.
Short Circuit Switch off Immediately
Overheat AC Mode: Switch to Bypass
Backup Mode: Switch off the UPS
Battery Low Alarm and Switch Off
Noise Suppression Complies with EN62040-2
Spike suppression Complies with EN61000-4-5
Heat Dissipation (at full linear load)*** Without Isolated Transformer Module <450W 10K: <600W
10KP: <550W
With Isolated Transformer Module <615W 10K: <1100W
10KP: <1050W
Leakage Current <3mA at Full Load
Computer Interface
Interface Type Standard RS232 Interface
Communication Slots 2nd RS232, USB, RS485, Relay Contact or SNMP Card
Mechanical
Dimensions (W x D x H) mm 440 x 680 x 88 440 x 680 x 132
Input/Output Connection Hardwire
External Battery Connection Plug-in & Play
Net Weight 24kg (52.9lbs) 26.0kg (57.3lbs)
Environmental
Operating Temperature 0-40°C (32-104°F)
Temperature Warning The battery design life is based on a temperature of 25°C (77°F), Ambient temperature above this range will affect battery life
Altitude 0~2000M/6600ft up to 40°C (104°F), 3000M/9900ft up to 35°C (95°F)
Humidity 90% RH Maximum, Non-Condensing
Noise <50dB (at 1M/3.3ft)
Agency Compliance
Quality Assurance ISO9001 Certified
Safety Standard EN62040-1-1, UL1778
EMC Standard EN62040-2, EN61000-3-2, EN61000-3-3, FCC Class A
Marks CE, cUL, UL
Battery Pack
Model BP Continuity 6K BP Continuity 10K
Battery Type 7Ah 9Ah
Maximum Quantity 20 pcs
Output Voltage 240Vdc
Weight Without Batteries 18.0kg (39.7lbs)
Weight With Batteries 52kg (115lbs) 68.0kg (149.8lbs)
Dimensions mm 132H x 440W x 680D
Inch 5.2H x 17.3 x 26.8D