Sentra

Highly efficient Line Interactive Sine Wave UPS with 0.9 output power factor

Optional external battery cabinets with “daisy-chainable” connections and dependable high rate charger provide extended backup and optimal runtime

Rack/tower convertible design with rotating LCD panel provides compact and flexible form factor

Advanced Automatic Voltage Regulation (AVR) lengthens battery life

Hot swappable battery function facilitates ease of maintenance

USB and RS232 interfaces, plus customer definable slot, provide additional communication flexibility

 

ModelVermogenAfmetingen (BxHxD)
Sentra XL 10001000 VA / 900 W440 x 88 x 491 mm
Sentra XL 15001500 VA / 1350 W440 x 88 x 491 mm
Sentra XL 22002200 VA / 1920 W440 x 88 x 701 mm
Sentra XL 30003000 VA / 2700 W440 x 88 x 701 mm
Models Sentra XL 1000 Sentra XL 1500 Sentra XL 2200 Sentra XL 3000
Input
Acceptable Voltage Range 83-159Vac or 160-300Vac
Voltage Window 110/120/127Vac or 220/230/240Vac +/-25%
Frequency 45~65Hz (auto-sensing)
Phase Single phase + ground
Output
Voltage Range Battery Mode 110/120/127Vac or 220/230/240Vac +/-5%
Frequency 50/60Hz Auto-sensing
Capacity 1000VA/900W 1500VA/1350W 2100VA/1920W 3000VA/2700W
Wave Form Pure Sine Wave
Transfer Time 4-6ms typical
Efficiency Line Mode: Up to 95%; Boost/Buck Mode: Up to 94%
Cold Start Yes
Battery
Type Sealed Lead Acid Maintenance-free
Capacity 12V/7AH 12V/9AH 12V/7AH 12V/9AH
Quantity 4 4 8 8
Voltage 24V 24V 48V 48V
Autonomy (80% load) 8.6mins 7.1mins 7.9mins 7.3mins
Recharge Time 5 hours to 90% after complete discharge at 100% load
Display
Status on LCD Line bypass, AVR Boost(Buck), Backup, Battery Level, Battery Low, Load
Level, Battery Fault, UPS Fault
Status on LED Line Mode, Battery Mode, and Fault
Self-Diagnostics Upon Power On and Software Control
Protection
Overload: Line Mode >100%-110% buzzer alarms only
>110%-120% for 10 min. and then shutdown
>120% shutdown after 1 cycle
Overload: Battery Mode >100%-120% buzzer alarms only
>120%-130% shutdown after 10 sec.
>130% shutdown after 1 cycle
Short Circuit: Line Mode Resettable Breaker
Short Circuit: Battery Mode Electronic Circuit
Low Battery: Alarm and Switch Off
EPO: UPS Shuts Down Immediately
Battery: Electronic System of Management of Battery Discharge
Heat Dissipation 96W 108W 192W 216W
Alarms
Acoustics and Display Mains Fault, Low Battery, Overload and Fault Conditions
Computer Interface
Interface Type Standard RS232 and USB
Communication Slots Dry Contact Card or SNMP card
Compatible Platforms Windows 95/98/NT/2000/XP/Vista/Win7, Novell Netware, Linux, Mac
Mechanical
Dimensions 88H x 440W x 491D (mm) 88H x 440W x x 701D (mm)
3.5H x 17.3W x 19.3D (inch) 3.5H x 17.3W x 27.6D (inch)
Input Connectors: 120Vac NEMA5-15P NEMA 5-20P NEMA L5-30P
Input Connectors: 230Vac IEC-320-C14 IEC-320-C20
Output Connectors: 120Vac (8) NEMA 5-15R (6) NEMA 5-15R
(2) NEMA 5-20R
(5) NEMA 5-15R
(2) NEMA 5-20R
(1) NEMA L5-30R
Output Connectors: 230Vac (8) IEC-320-C13 (8) IEC-320-C13, (1) IEC-320-C19
Net Weight (120Vac) 25kgs (51lbs) 27.8kgs (61lbs) 41.8kgs (92lbs) 47.8kgs (105lbs)
Net Weight (230Vac) 25kgs (51lbs) 27.8kgs (61lbs) 42kgs (93lbs) 46.2kgs (102lbs)
Environmental
Operating Temperature 0 to 40°C (30 to 104°F)
Warning Temperature The battery design life is based on a temperature of 25°C (77°F)
Ambient temperature above this range will affect battery life
Altitude 0-2000M up to 40°C (104°F); 0~3000M up to 35°C (95°F)
Humidity 90% RH Maximum, No Condensing
Noise Line Mode: 40 dB Max; Bat. Mode: 45 dB Max.
Agency Compliance
Quality ISO 9001 certified manufacturing
Security EN62040-1-1, UL1778
Performance EN62040-3
Standard EMC EN62040-2, EN61000-3-2, FCC Class A
Marking CE, UL, cUL, FCC